Abstract
Paediatric wrist fractures are routinely managed with closed reduction and a molded cast. Gap(GI) and Cast indices(CI) are useful in predicting re-displacement following application of cast. Over 6 months we audited the efficacy of molded cast application following closed reduction of distal radial fractures in paediatric patients. The standard was that proposed by Malviya et al where GI >0.15 and CI >0.8 indicate an increased risk of re-displacement. Age, date and time of operation and surgeon's grade were collected. Pre-op displacement, post-reduction GI and CI and subsequent re-displacement were measured using imaging. Post audit intended changes to practice were presented to all surgeons, a “one-pager” was placed above scrub sinks. Re-audit was conducted at 1 year. The audit and re-audit included 28 and 24 patients respectively. Cast molding (CI) improved minimally following intervention (32% to 29%). Cast padding (GI) improved significantly (82% to 63%). Loss of reduction decreased slightly (14% to 12%), this was not accurately predicted by GI and CI in the re-audit. Audit demonstrated that casts were loose, over-padded and did not hold reduction adequately. Re-audit demonstrated that tighter, less padded but still inadequately molded casts were being applied with minimal change in loss of reduction.