Abstract
Anterior positioning of a cephomedullary nail in the distal femur occurs in up to 88% of cases. This is considered to occur because of a mismatch between the radius of curvature of the femur and that of available implants. The hypothesis for this study was that the relative thicknesses of the cortices of the femur (referenced off the linea aspera) change with age and determine the final position of intramedullary implants.
This study used the data from CT scans undertaken as part of routine clinical practice in 919 patients with intact left femora (median age 66 years, 484 male and 435 female). The linea aspera and transverse intervals were plotted on a template femur between 25% – 60% femoral bone length (5% increments) and mapped automatically to all individual femora in the database with measurements taken in the plane of the linea aspera.
The linea aspera was found to be internally rotated as compared to the sagittal plane referenced off the posterior femoral condyles. An age related change in the posterior/anterior cortical thickness ratio was demonstrated. The >80 year old cohort shows a significantly disproportional posterior/anterior ratio increase of 70.0% from 25–50% bone length as compared to 48.1% for the <40 year old cohort (p<0.05).
This study has shown that assessment in the sagittal plane may be inaccurate because of rotational changes in the linea aspera. The centering influence of the corticies is lost with age with a relative thinning of the anterior cortex and thickening of the posterior cortex moving distally in the femur. This has a direct influence on the positioning of intramedullary implants explaining the preponderance of anterior malpositioning of intramedullary implants in the elderly.