Abstract
Infected nonunion of the femur or tibia diaphysis requires resection of infected bone, stabilization of bone and reconstruction of bone defect. External fixation of the femur is poorly tolerated by patients. In 2004 authors introduced in therapy for infected nonunions of tibia and femur diaphysis coating of IMN with a layer of antibiotic loaded acrylic cement (ALAC) containing 5% of culture specific antibiotic.
Seven patients with infected nonunion of the diaphysis of femur (2) and tibia (2) were treated, aged 20–63 years, followed for 2–9 years (average 5,5 years). All have been infected with S. aureus (MSSA: 2 and MRSA: 4) or Staph. epidermidis (1) and in one case with MRSA and Pseudomonas aeruginosa. All patients underwent 3 to 6 operations before authors IMN application. Custom-made IMN coated with acrylic cement (Palamed) loaded fabrically with gentamycin with admixture of 5% of culture-specific antibiotic: vancomycin (7 cases) and meropeneme (1 case) was used for bone stabilization. Static interlocking of IMN was applied in 4 cases and dynamic in 2 cases. In 1 case the femur was stabilized with IMN without interlocking screws. In 2 cases IMN was used for fixation of nonunion at docking site after bone transport. In 3 cases ALAC was used as temporary defect filling and dead space management. In one case after removal of IMN coated with ALAC, a new custom made Gamma nail and tubular bone allograft ranging 11 cm was used for defect reconstruction.
Infection healing was achieved in all 7 cases, bone union was achieved in 4 from 7 cases. In 1 case of segmental diaphyseal defect ranging over 12 cm infection was healed, but bone defect was not reconstructed. This patient is waiting for total femoral replacement. In another case of segmental defect of 11 cm infection is healed, but allograft substitution and remodeling by host bone is poor. In the 3rd case of lacking bone healing, the 63 year old patients was noncooperative and not willing to walk in walker with weight bearing. This patient refused further treatment.
Custom-made intramedullary nail coated with a layer of acrylic cement loaded with 5% of culture specific antibiotic can provide local infection control, offer comfortable bone stabilization, and replace standard IM nail in therapy for difficult to treat infected diaphyseal nonunion of femur or tibia.