Abstract
While short stem designs are not a new concept, interest has surged with increasing popularity of less invasive techniques. If the goal of the tapered stem is to load preferentially proximally, why do we need a stem at all? Perhaps the only reason to use a tapered, long stem is to prevent varus; however, studies have shown that varus malalignment of a tapered stem does not affect results. Short stems are easier to insert, especially when using an anterior approach such as the anterior supine intermuscular in which the proximal femur is elevated anteriorly from the wound during stem insertion. Femoral preparation can be accomplished with straightforward broaching of the canal, without use of reamers. Short stems are bone conserving. They violate less femoral bone stock, providing more favorable conditions should a revision be required. However, ease of insertion and bone conservation matter little if not supported by clinical results. Thus, we reviewed our early experience with 2094 patients undergoing 2457 primary THA using short, tapered titanium, porous plasma spray-coated femoral components since January 2006 at our center. The TaperLoc Microplasty stem (Biomet, Warsaw, IN) has been used in 1881 THA, and the TaperLoc Complete Microplasty stem (Biomet) in 576. Patient age averaged 63.6 years. Increased offset was used in 1990 hips (81%). The surgical approach was less invasive direct lateral (LIDL) in 1194 THA (49%), anterior supine intermuscular (ASI) in 1117 (46%), and standard direct lateral (Std) in 146 (6%). Follow-up averaged 20 months. Thirty-five stems (1.4%) have been revised: 15 for infection (12 LIDL, 3 ASI), 1 same day revision for intraoperative femoral shaft perforation (Std), 1 at 3 days for patellar dislocation (LIDL), 2 for early subsidence (1 LIDL, 1 ASI), 13 for periprosthetic femoral fracture (1 Std, 12 ASI), 2 for aseptic loosening (1 LIDL, 1 ASI), and 1 stem well fixed (ASI) removed for loose cup and unable to disarticulate trunnion.
What lessons have we learned? First, we usually require one or two diameter sizes larger with short porous tapered stem versus the standard length version of the same design. The surgeon should be aggressive with sizing, pushing to the largest size possible. Use the broach like a rasp. Drive the component in valgus during insertion. Upon seating the component, do a trial reduction using the shortest available neck length. The component will generally sit slightly prouder than the broach and may require additional effort to seat completely.
Conservation of existing bone stock, compatibility with soft-tissue sparing surgery, more physiologic loading of the proximal femur, and versatility with varying femoral anatomy make the short taper an attractive implant option. The tapered wedge short stem represents the natural evolution of joint arthroplasty to a smaller, less-invasive, and more efficient implant.