Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Foot & Ankle

A simplified, validated method for measuring fibular reduction on CT scan

British Orthopaedic Foot & Ankle Society (BOFAS)



Abstract

Introduction:

Fibular malreduction is a common and important cause of pain after surgical fixation following a syndesmosis injury, but it is unclear which components of malreduction correspond to clinical outcome. Plain radiographs have been shown to be unreliable at measuring malreduction when compared to CT scans. A number of published methods for measuring fibular position rely on finding the axis of the fibula. Elgafy demonstrated that fibular morphology varies greatly, and some studies have demonstrated difficulty finding the fibular axis.

Methods:

We developed a new method of measuring the distal fibular position on CT images. We used CT studies in 16 normal subjects. Two assessors independently measured the ankle syndesmosis using the Davidovitch method, and our new protocol for fibular AP position, diastasis and fibular length.

Results:

We demonstrated that after statistical analysis (Pearson Product Moment Correlation) our method showed improved inter-observer reliability (r = 0.99 and 0.95 vs 0.59 and 0.78 respectively) for diastasis and AP translation, and improved intra-observer reliability (r = 0.99 and 0.99 vs 0.91 and 0.97 respectively). We found inter and intra observer reliability of 0.80 and 0.91 respectively for fibular length, but were unable to find a novel, accurate method for measuring fibular rotation.

Conclusions:

Our method is a new, simple, accurate and reproducible system for measuring the ankle syndesmosis. We believe that this method could be used to assess fibular reduction after obtaining CT images of the uninjured side for comparison.