EXCHANGE NAILING FOR TIBIAL DIAPHYSEAL FRACTURE NON-UNIONS: RISK FACTORS FOR FAILURE

Scottish Committee for Orthopaedics and Trauma (SCOT)



Abstract

The aim of this study was to identify risk factors for failure of exchange nailing in tibial diaphyseal fracture non-unions. The cohort comprised 99 tibial diaphyseal fracture non-unions treated by exchange nailing. The mean age of the patients at exchange nail surgery was 36 years. The median time from primary fixation to exchange nailing was 6.4 months. The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union. Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union.

Multiple causes for non-union were found in 31.3% cases, with infection present in 32.3%. Further exchange procedures were required in 35.4%, 7.1% required the use of other fixation modalities. Union was ultimately achieved in 97.8%. The median time to union was 8.7 months. Univariate analysis revealed that cigarette smoking, an atrophic pattern of non-union and infection were predictive for failure of exchange nailing (p<0.05). Multi-regression analysis found that only infection was statistically significantly predictive (p<0.05) of exchange nail failure.

Exchange nailing is an effective treatment for tibial diaphyseal non-unions even in the presence of infection. Smoking, atrophic pattern of non-union and infection are associated with an increased risk of further fixation surgery.