Radiolucent lines in total shoulder arthroplasty around the glenoid component are not uncommon in post-operative x-rays and the incidence varies. A certain percentage progress and as the lines enlarge can lead to component loosening. One study reported a 9% incidence at 2 years and 27% incidence at 5 years. A recent long term study (15 to 20 years) reported a 73% incidence. Radiolucent lines can be caused by anatomy (posterior glenoid wear) or pathology (inflammatory arthritis) as well as technical factors such as glenoid implant design (metal back) and improper implantation techniques where the prosthesis is not fully seated or cement is used to fill a defect. Every attempt should be made to avoid lucent lines. Minimal bone should be removed from the glenoid vault and a pressure injection type of insertion is helpful in getting the cement into the cancellous bone. Furthermore a peg type of glenoid implant rather than a keel type is preferred as this has been associated with a lower incidence of radiolucent lines.