Abstract
Contracture of the anterior musculature causes posterior humeral head subluxation and results in a posterior load concentration on the glenoid. This reduced contact area causes glenoid wear, humeral medialisation and eventually posterior instability. After arthroplasty that does not correct for this, posterior wear stress increases in the implant, across the cement mantle and bone thus increasing the risk of aseptic loosening over time.
Correction of the posterior wear pattern at the time of arthroplasty of the shoulder is recommended. Asymmetric reaming of the glenoid has been recommended as a means to correct this deformity but leads to producing a smaller glenoid which is medialised. This shortening of the glenoid causes the stabilising muscle envelope to shorten and the glenoid vault to become much smaller in volume. These potential changes may have a destabilising effect on the implant leading to early loosening and secondary failure of the prosthetic implant.
Other options include using an implant to make the correction of the deformity such as augmented glenoid components. Early uses of these implants were not successful mainly due to the design flaws of the early implants. Newer implants have made design changes to overcome these early failures. CT scan evaluation is important to determine the degree of correction that is needed to balance the glenohumeral joint. Correcting the deformity and keeping the muscle envelope at the appropriate tension may lead to better long term outcomes. These implants are currently in use but long term outcome studies are not yet available to determine their ultimate values to the patients.