Abstract
Summary Statement
This is the first report of a new technique for unicompartmental to total knee arthroplasty revision surgery in which patient specific guides are formed based on preoperative CT imaging. This technique can help to make revision surgery less technically demanding.
Introduction
Unicompartmental to total knee arthroplasty revision surgery can be a technically demanding procedure. Joint line restoration, rotation and augmentations can cause difficulties. This study describes a new technique in which single way fitting guides serve to position knee system cutting blocks.
Methods
Preoperatively an image of the distal femur and proximal tibia are formed using CT-scanning. This image is used to create patient specific guides that fit in one single position on the contours of the bone and prosthesis in situ. These guides are fixed with pins and thereafter removed. The pins determine the position of the cutting blocks. Ten consecutive revisions were performed using this technique.
Results
All guides fitted well. All femoral prostheses were properly inserted using this technique. One proximal tibia however did not have not enough bonestock so that conversion to intramedular referencing was performed. This was to be expected after the preoperative planning. Postoperative position of the prosthesis was good in all cases.
Discussion
This new technique can help to make unicompartmental to total knee arthroplasty less demanding. Problems such as the need for augmentations can be predicted in the preoperative planning. Radiation issues due to CT scanning are limited. The instrumentation needs to be redesigned in order to make this technique work in cases with minimal bonestock present.