EFFECT OF THE CLINICAL CT IMAGE RESOLUTION ON THE FINITE ELEMENT MODEL OF HUMAN CANCELLOUS BONE

8th Combined Meeting Of Orthopaedic Research Societies (CORS)



Abstract

Summary

At the clinical CT image resolution level, there is no influence of the image voxel size on the derived finite element human cancellous bone models

Introduction

Computed tomography (CT)-based finite element (FE) models have been proved to provide a better prediction of vertebral strength than dual-energy x-ray absorptiometry [1]. FE models based on µCTs are able to provide the golden standard results [2], but due to the sample size restriction of the µCT and the XtremeCT machines, the clinical CT-based FE models is still the most promising tool for the in vivo prediction of vertebrae's strength. It has been found [3] that FE predicted Young's modulus of human cancellous bone increases as the image voxel size increases at the µCT resolution level [3]. However, it is still not clear whether the image voxel size in the clinical range has an impact on the predicted mechanical behavior of cancellous bone. This study is designed to answer this question.

Methods

For this study, 6 thoracolumbar vertebrae (Th12) obtained from the female donors were scanned in the non-dissected cadavers under 2 different resolutions – group A: 120 kVp, 100 mAs, with a resolution of 0.29×0.29×1.3 mm3; group B: 120 kVp, 360 mAs, with a resolution of 0.18×0.18×0.6 mm3. A solid calibration phantom (QRM-BDC) was placed beneath the cadavers during the scans.

Cuboids with the size of 12.3×12.3×14.3 mm3 were cropped from the center of each vertebral body. The FE model was created by converting each image voxel into hexahedron (C3D8). Inhomogeneous material property was defined for the cuboid [4], i.e. the image greyscale value were firstly calibrated into the bone mineral density (BMD), then the Young's modulus and yield stress were calculated from the BMD [5] for each element. Statistical analysis was performed to compare the FE predicted mechanical properties between the groups and the significance level was set to 95% (α=0.05).

Results

The trabecular structure is more clearly mimicked in the models from group B than those from group A. The modulus (mean ± SE) in group A is 5.9% higher than that in group B (193.33 ± 31.67 MPa vs. 182.50 ± 27.07 MPa). The yield strength (mean ± SE) in group A is 6.4% higher than that in group B (0.99 ± 0.21MPa vs. 0.93 ± 0.17MPa). However, the paired t-test shows there is no significant difference of the mechanical properties in the two groups (p=0.109 for the modulus and p=0.234 for the yield strength).

Discussion

This study shows that there is no influence of the voxel size on the clinical CT derived FE cancellous bone models. This finding can help choose a better, less invasive CT protocol for the patient when creating a clinical CT image based FE model.

Acknowledgements

This study is financially supported by the Federal Ministry of Education and Research and the state of Hamburg, Germany.