CAPSTAN SCREW REPAIR: A NOVEL TWO ROW MINI-OPEN APPROACH

The South West Orthopaedic Club (SWOC) Spring Meeting



Abstract

Eighty-eight consecutive patients with symptomatic rotator cuff tears were entered in to a prospect study with a novel technique of open double row repair using a ‘Capstan’ screw technique. The medial row has standard anchors, but the lateral suture row is a 35mm × 6.5mm ‘Capstan' screw. This allows up to 28 suture bridges to be taken from the medial row to the lateral row compressing the footprint and spreading the load. This creates a very robust repair or ‘bulletproof repair’. This was used for medium to large isolated supraspinatus tears

Each patient had a pre and post operative Oxford Shoulder Score (OSS), American Shoulder and Elbow Score (ASES Score). The mean pre-operative OSS was 22 (maximum 48) and the mean post-operative OSS was 45, (p < 0.0001). Flexion improved from a mean of 117° to 172° (p < 0.0001). The clinical re-tear rate was 3.4%. 95% were satisfied with the procedure. There were no deep infections. 18% had transient stiffness, 6% stiffness at one year but none severe enough to warrant release. There were no instances of deltoid dysfunction.

This demonstrates excellent results in terms of OSS, patient satisfaction and function. Clinical re-tear rate is markedly reduced in comparison to previous literature.