When performing scarf osteotomies some surgeons use intraoperative radiography and others do not. Our experience is that when using intraoperative radiography we often change the osteotomy position to improve the correction of the hallux valgus angle and sesamoid position.
We report the results of a single surgeon series of 62 consecutive patients who underwent a scarf osteotomy for hallux valgus. The first 31 patients underwent surgery without the use of intraoperative radiographs and the subsequent 31 patients underwent surgery with the use of intraoperative radiographs, this reflects a change in the surgeons practice. Hallux valgus angle, intermetatarsal angle, distal metatarsal articular angle and sesamoid position using the Hardy Clapham grading system were recorded. All patients had measurements recorded from weight baring radiographs taken pre operatively as well as at 6 and 12 weeks post operatively. Intraoperative measurements were also recorded for all patients in the intraoperative radiography group.
The mean hallux valgus angle preoperatively was 28.5° in the control group and 30.5° in the intraoperative radiography group. The mean hallux valgus angle in the control group at 6 weeks was 12.4° and at 12 weeks was 12.6°. The mean hallux valgus angle in the intraoperative radiography group at 6 weeks was 10.5° and at 12 weeks was 9.8°.
The median sesamoid position pre operatively was 4 for both groups. At 6 and 12 weeks the sesamoid position improved by a median of 1 position in the control group and 2 positions in the intraoperative radiography group (p<0.05).
We recommend that surgeons who do not routinely use intraoperative radiography undertake a trial of this. We have found that the use of intraoperative radiography improves the correction of hallux valgus angle and sesamoid position. These have been shown to increase patient satisfaction and reduce recurrence.