REPRODUCTION OF ATROPHIC NONUNION BY A FEMORAL DEFECT MODEL IN RAT

International Society for Fracture Repair (ISFR)



Abstract

Introduction

what size of defect is optimal for creating an atrophic nonunion animal model has not been well defined. Our aim in this study was to establish a clinically relevant model of atrophic nonunion in rat femur by creation of a bone defect to research fracture healing and nonunion.

Materials and methods

We used 30 male Fischer 344 rats (aged 10–11 weeks), which were equally divided into six groups. The segmental bone defects to a single femur in each rat were performed by double transverse osteotomy, and different sized defects were created by group for each group (1 mm, 2 mm, 3 mm, 4 mm, 5 mm and 6 mm). The defects were measured and maintained strictly by using an original external fixator. The periosteum for each defect was stripped both proximally and distally. Thereafter, these models were evaluated by radiology and histology. Radiographs were taken at baseline and at intervals of two weeks over a period of 8 weeks. Atrophic nonunion was defined as a lack of continuity and atrophy of both defect ends radiologically and histologically at eight weeks.

Results

In the 1 mm defect group, all defects had healed. In the 2 mm group, one-fifth remained atrophic nonunion. In the 3 mm group, three-fifths had atrophic nonunion, and all of the defects of groups of 4 mm and over were atrophic nonunion.

Conclusion

This study showed that we were able to predictively produce an atrophic nonunion animal model by creating defects of at least 4 mm in the Fischer 344 rat femur.