Abstract
Introduction
We present our experience of the coned hemi-pelvis (‘ice-cream’ cone) implant, using an extended posterior approach to the hip joint, in the management of pelvic bone loss and pelvic discontinuity.
Methods
Retrospective study conducted utilising a prospectively collected database. Patients who underwent an ice-cream cone reconstruction between August 2004 – September 2011 were identified. All had a posterior approach to the hip. Femur prepared in the standard fashion. A variety of femoral components used. Demographic data was recorded along with the indication for surgery and outcomes.
Results
16 patients identified. Mean age was 62.2 years. 5 (31.25%) male. 11 (69.75%) female. Indications included; multiple hip revision surgery 4(25%); post Gridlestones for severe hip dysplasia 1 (6.25%); peri-acetabular metastatic deposits 11 (68.75%) from breast, renal, endometrial, prostatic, myeloma primary malignancies. Mean follow-up was 32.06 months. Complications; 1 intra-operative death from tumour embolus; 1 dislocation; 1 superficial surgical site infection. 3 deaths from their primary malignancy. Mean time from prosthesis implantation to death was 14.5 months. All patients at last follow-up were mobilizing. No implant has needed to be revised.
Discussion
Pelvic bone loss provides reconstructive challenges. The coned hemi-pelvis is simple to make, easy and versatile to use even when there is little pelvis remaining. It provides a method of negotiating hip reconstruction in patients with severe pelvic bone loss. Orthopaedic surgeons are familiar with the posterior approach to the hip. The ice-cream cone implant can therefore be placed with ease using this well-known approach to the hip.