EXTRACORPOREAL IRRADIATION – WHY IT IS BEST TREATED OUTSIDE THE BODY!

Australian Orthopaedic Association Limited (AOA)



Abstract

Extracorporeal irradiation of resected bone segments has been used for pelvic reconstruction for 12 years in our unit. The technique allows for a perfect fit, preservation of muscle attachments, and thus, facilitating reconstruction, more rapid osteotomy of autograft bone, low cost, and a low infection rate.

Of particular interest is its use in children; revascularisation appears more complete with irradiated autograft, as compared to allograft. There is sparing of adjacent growth plates if the irradiation is given outside the body, whereas external beam radiation would destroy the proximal femoral growth plate—leading to significant leg length discrepancy.

Avoiding external beam irradiation also removes any risk of late radiation induced sarcoma and removes the late effects of soft tissue fibrosis due to external beam irradiation.

Twenty-seven pelvic reconstructions have been done over a 12-year period, with three failures due to infection and seven due to further disease. Four of these have been for de-differentiated chondrosarcoma of the pelvis, where local recurrence led to failure. In the presence of de-differentiated pelvic chondrosarcoma, we do not recommend this form of reconstruction.

Long term functional outcome scores for the first 50 cases completed between August 1996 and June 2003 gave a TESS score of 82% and MSTS score of 78%. This is more than comparable to published series using other forms of reconstruction.