header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

HISTOLOGICAL CHARACTERISATION OF A NEW MURINE FRACTURE MODEL WITH LOCKING PLATE STABILISATION

Australian Orthopaedic Association Limited (AOA)



Abstract

To elucidate the molecular biology of fracture healing, murine models are preferred. We performed a study with the first internal fixation system that allows studying murine fracture healing in a controlled mechanical environment, to characterise the timing of the fracture healing cascade with this model, based on a histological evaluation.

Femoral osteotomies were performed in 68 male C57BL/six mice and stabilised with locking internal fixation plates in either stiff, or defined, flexible configurations. Healing progression was studied at 10 time points between 3 and 42 days post- surgery. After surgery, mice were radiographed to confirm the correct implant positioning. After sacrifice, the extracted femora were processed for decalcified histology. Thin sections were taken as serial transverse sections and stained for subsequent histomorphometric analysis and three-dimensional reconstruction of the different fracture callus tissues.

The surgery was successful in 62 animals. Only six6 (8.8%) animals had to be sacrificed due to complications during surgery. The post-operative radiographs demonstrated a high reproducibility of implant positioning and no implant failure or screw loosening occurred during the experimental period. The improved consistency in surgical technique leading to more uniform results represents a key advantage of this system over other mouse fracture healing models. As such, it may allow a reduction in the sample size needed in future murine fracture healing studies. The histological evaluation confirmed the lack of a periosteal callus, and exclusively endosteal, intramembraneous bone formation in the bones stabilised with the stiff implants. The bones that were stabilised with the more flexible internal fixation plates showed additional endochondral ossification with extensive, highly asymmetrical, periosteal callus formation.

Our results demonstrate that this murine fracture model leads to different healing patterns depending on the flexibility of the chosen plate system. This allows researchers to investigate the molecular biology of fracture healing in different ossification modes by selection of the appropriate fixation.