Full Access

General Orthopaedics

CLINICAL OUTCOME OF ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH FOUR FOLD HAMSTRING TENDON GRAFT USING TRANSFIX AND BIOABSORBABLE INTERFERENCE SCREW FIXATION

Australian Orthopaedic Association Limited (AOA)



Abstract

Purpose

To evaluate the results of quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with four fold Hamstring Tendon Graft using Transfix and Bioabsorbable Interference Screw Fixation.

Study Design

Retrospective review.

Methods

Sixty-five patients (66 knees) were retrospectively identified by chart review as having undergone quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction, with four fold Hamstring Tendon Graft, using Transfix and Bioabsorbable Interference Screw Fixation. All patients underwent a minimum two-year follow-up.

Results

Data were collected on 48 knees in 47 patients (73%) at an average 30.2 months (range 24 to 43) after surgery. Thirty-six patients (37 knees) returned for clinical evaluation (56% return) and subjective follow-up only was obtained in 11 patients (17%). The mean Lysolm knee score was 91 (range, 45 to 98), with a mean of 97 for the uninvolved knee. The mean Tegner activity score was 5.7 (range 3 to 7). The KT-1000 arthrometer mean side-to-side difference for manual maximum displacement was 2.03 mm (range -1 to 8). The mean International Knee Documentation Committee knee score was 83 (range 47 to 100). Patients who underwent associated partial meniscectomy or meniscal repair had significantly lower International Knee Documentation Committee scores than patients without associated procedures (P < 0.01).

Conclusions

Quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation is comparable with other methods of anterior cruciate ligament reconstruction in terms of patient satisfaction, knee stability, and function.