header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

Clinical Outcome of Hip Resurfacings Depends on Design

The International Society for Technology in Arthroplasty (ISTA)



Abstract

Surface arthroplasty or resurfacing represents a significant development in the evolution of hip replacement. A hip resurfacing arthroplasty (HRA) is a bone conserving alternative to total hip arthroplasty (THA) that restores normal joint biomechanics and load transfer and ensures joint stability. Metal-on-metal (MoM) bearings have been preferred for these large diameter articulations because of their lower volumetric wear and smaller particulate debris compared to metal-on-poly-ethylene bearings. Of the many engineering factors which have contributed to the success of the MoM bearing, the metallurgy, diametral clearance, sphericity and surface finish were thought to be most important. More recently, adverse reactions to metal particles and ions generated by wear and corrosion of the metal surfaces have focused the attention on the importance of coverage angle and cup positioning. Currently, the scientific consensus is that cup coverage angle, diametral clearance and metallurgy have their importance in that order. Precise understanding of manufacturing variables is imperative in obtaining clinical consistency and safety in the patient. It is important to examine femoral fixation, bone remodelling, and wear of MoM implants. For the second and third generation MoM HRA various designs and biomaterials have been used. We have conducted a randomised, controlled trial comparing 9 different hip resurfacing prostheses. Clinical and radiographic outcome and whole blood, serum and urine metal ion levels are evaluated at 6 months, 1 year and 2 years in 180 patients with 9 different HRA designs and the differences are analyzed. Besides, the design quality of the 9 different metal-on-metal prostheses and their accessory instruments have been judged during the operation. The Durom with its Metasul history may claim a metallurgic advantage, and in combination with the highest coverage angle of all cups, it may be the best wear couple, as suggested by low ion measurements. However, as discussed above, an optimal bearing alone is not sufficient to achieve a successful hip resurfacing.


∗Email: koen.desmet@skynet.be