Full Access

General Orthopaedics

FEMORAL BLOOD FLOW DURING HIP RESURFACING: A COMPARISON OF TWO APPROACHES USING LASER DOPPLER FLOW MEASUREMENT

British Orthopaedic Association (BOA) 2006



Abstract

We used a laser Doppler flow-meter with high energy (20 m W) laser (Moor Instruments Ltd. Milwey, UK) to measure the blood flow to the femoral head during resurfacing arthroplasty.

Twenty-four hips were studied; 12 underwent a posterior approach and twelve a Ganz's trochanteric flip osteotomy. The approach was determined according to surgeon preference. Three patients were excluded, The exclusion criteria were previous hip surgery, history of hip fracture and avascular necrosis (AVN). All patients had the hybrid implant with cemented femoral component.

During surgery a 2.0mm drill bit was passed via the lateral femoral cortex to the superior part of the head neck junction. The position was confirmed using fluoroscopy. The measurements were taken during five stages of the operation: when the fascia lata was opened (baseline), at the end of soft tissue dissection, following dislocation of the hip, after relocation back into the socket, after inserting the implants prior to closing the soft tissues and, finally, at the end of soft tissue closure.

The results were analysed and the values were normalised to a percentage of the baseline value. We found a mean drop of 38.6 % in the blood flow during the posterior approach and a drop of 10.34% with the trochanteric flip approach. The significant drop occured between the baseline (1st stage) and the end of the soft-tissue dissection (2nd stage). In both groups the blood flow remained relatively constant afterwards.

Our study shows that there is a highly significant drop in blood flow (p<0.001) during the posterior approach compared with the trochanteric flip approach.