Abstract
Introduction
Secondary osteoarthritis in a dysplastic hip is a surgical challenge. Severe leg length discrepancies and torsional deformities add to the problem of inadequate bony support available for the socket. Furthermore, many of these patients are young and wish to remain active, thereby jeopardising the long-term survival of any arthroplasty device.
For such severely dysplastic hips, the Birmingham Hip Resurfacing (BHR) device provides the option of a dysplasia component, a hydroxyapatite-coated porous uncemented socket with two lugs to engage neutralisation screws for supplementary fixation into the solid bone of the ilium more medially. The gap between the superolateral surface of the socket component and the false acetabulum is filled with impacted bone graft.
Methods and results
One hundred and thirteen consecutive dysplasia BHRs performed by the senior author (DJWM) for the treatment of severely arthritic hips with Crowe grade II and III dysplasia between 1997 and 2000 have been reviewed at a minimum five year follow-up. There were 106 patients (59M and 47F). Eighty of the 113 hips were old CDH or DDH, 29 were destructive primary or secondary arthritis with wandering acetabulae and four were old fracture dislocations of the hip. Mean age at operation was 47.5 years (range 21 to 68 years – thirty-six men and forty-four women were below the age of 55 years).
There were two failures (1.8%) out of the 113 hips at a mean follow-up of 6.5 years (range 5 to 8.3 years). One hip failed with a femoral neck fracture nine days after the operation and another failed due to deep infection at 3.3 years.
Conclusion
The dysplasia resurfacing device offers a good conservative arthroplasty option for these severely deficient hips.