Abstract
Aim
The primary objective is to evaluate the diagnostic performance of inoculating homogenized tissue and bone biopsies in blood culture bottles (BCB) for patients with (suspected) orthopaedic device-related infections. As secondary objective the time to positivity (TTP) of BCB and Wilkins-Chalgren broth (conventional method) will be evaluated.
Method
Patients undergoing revision surgery due to suspected or proven fracture-related infection (FRI) or periprosthetic joint infection (PJI) according to respectively Consensus definition and EBJIS definition are included.1,2 A minimal of three macroscopic infected/inflamed tissue/bone samples are collected in a container with saline and glass beads. 1.5 mL of the homogenized suspension is inoculated in BacT/ALERT FA and FN Plus bottles for 14 days. The remaining suspension is inoculated in Wilkins-Chalgren broth for 10 days and subcultured when cloudy or after 10 days. TTP is defined as the time until definite identification of the pathogen in the Laboratory Information System.
Results
Up to now, 25 patients have been included, 11 (44%) had concordant results in BCB and the CM. In 11 patients cultures showed negative results for both methods. Three patients tested positive with BCB but remained negative with the same pathogen in CM. In the first patient, the CM failed to identify anaerobic bacteria (i.e. Fusobacterium nucleatum). In the second patient, three BCB were positive with Staphylococcus capitis. The third patient showed an infection with Escherichia coli, which was detected in all samples from the BCB, while all cultures obtained with the CM remained negative. A possible explanation for this discrepancy could be that this patient already received antibiotic therapy. BCB contain resins, which are capable of neutralizing antibiotic activity. Another case illustrating superiority of BCB involved an infection with Cutibacterium acnes, which showed positivity in six BCB, while only three were positive using the CM. We observed the shortest TTP with BCB. The median TTP of BCB was 32.0 hours (IQR 29.8) compared to a median TTP of 77.5 hours (IQR 107.6) when culturing with the CM.
Contamination was seen in three patients with both methods, in eight patients contamination was only seen with the CM. For the remaining 14 patients no contamination was found.
Conclusions
The results in this ongoing study indicate that the recovery of pathogens and TTP is better using BCB compared to CM. In addition, contamination occurs less frequently with the BCB method. Culturing tissue or bone biopsies in BCB seems a promising and faster detection method.