Abstract

Background

Recent large studies of third-generation minimally invasive hallux valgus surgery (MIS) have demonstrated significant improvement in clinical and radiological outcomes. It remains unknown whether these clinical and radiological outcomes are maintained in the medium to long-term. The aim of this study was to investigate the five-year clinical and radiological outcomes following third-generation MIS hallux valgus surgery.

Methods

A retrospective observational single surgeon case series of consecutive patients undergoing primary isolated third-generation percutaneous Chevron and Akin osteotomies (PECA) for hallux valgus with a minimum 60 month clinical and radiographic follow up. Primary outcome was radiographic assessment of the hallux valgus angle (HVA) and intermetatarsal angle (IMA) pre-operatively, 6 months and ≥60 months following PECA. Secondary outcomes included the Manchester-Oxford Foot Questionnaire, patient satisfaction, Euroqol-5D Visual Analogue Scale and Visual Analogue Scale for Pain.

Results

Between 2012 and 2014, 126 consecutive feet underwent isolated third-generation PECA. The mean follow up was 68.8±7.3 (range 60–88) months. There was a significant improvement in radiographic deformity correction; IMA improved from 13.0±3.0 to 6.0±2.6, (p < 0.001) and HVA improved from 27.5±7.6 to 7.8±5.1. There was a statistically significant but not clinically relevant increase of 1.2±2.6° in the HVA between 6 month and ≥60 month radiographs. There was an increase in IMA of 0.1±1.6º between 6 month and ≥60 month radiographs which was not statistically or clinically significant. MOXFQ Index score at ≥follow up was 10.1±17.0. The radiographic recurrence rate was 2.6% at final follow up. The screw removal rate was 4.0%.

Conclusion

Radiological deformity correction following third-generation PECA is maintained at a mean follow up of 68.8 months with a radiographic recurrence rate of 2.6%. Clinical PROMs and patient satisfaction levels are high and comparable to other third-generation studies with shorter duration of follow up.