Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

EFFICACY AND SAFETY OF “SLEEPER PLATE” IN TEMPORARY HEMI-EPIPHYSIODESIS AND THE OBSERVATION OF “TETHERING”

The Canadian Orthopaedic Association (COA) and Canadian Orthopaedic Research Society (CORS) Annual General Meeting, Quebec City, Quebec, Canada, 8–11 June 2022. Part 2 of 2.



Abstract

Guided growth is commonly performed by placing an extra-periosteal two-hole plate across the growth plate with one epiphyseal and one metaphyseal screw. Recent work by Keshet et al. (2019) investigated the efficacy of the removal of the metaphyseal screw only (“sleeper plate”) after correction. They concluded the practice to be unnecessary as only 19% of patient show recurrence of deformity. The aim of this study is to examine the incidence of rebound and undesired bony in-growth of the plate (“tethering”) after metaphyseal screw removal only.

In this retrospective case series, patient data on 144 plates inserted around the knee was obtained. Plates still in situ (n=69) at time of study and full hardware removal (n=50) were excluded. The remaining 25 plates had a metaphyseal screw only removed after deformity correction. We analyzed the rate of re-bound, tethering and maintenance of correction in two age groups at latest follow-up for a mean of 3.5 years (1.25 to five). Fisher's exact test with Freeman-Halton extension was used to analyze the two by three contingency table.

Twenty-five plates were identified as “sleeper plates” in our series. 13 plates (52%) maintained the achieved correction after a mean of 21 months (four to 39), nine plates (36%) required screw re-insertion due to rebound after a mean of 22 months (12-48) from screw removal, and four plates (16%) showed tethering with undesired continuation of guided growth after a mean of 14 months (seven to 22) from screw removal. Younger patients (years at time of plate insertion) had higher rates of rebound and tethering (p=.0112, Fisher's exact test). All Tethering occurred in titanium plates, none occurred in steel plates.

The sleeper plate is an acceptable treatment strategy for coronal deformities around the knee. Rebounding and tethering are potential outcomes that occur in younger patients and should be disclosed to patients; titanium plates may increase the risk of tethering, however further long-term follow-up is needed. We stress the importance of close post-operative follow up to identify tethering early and prevent over correction.

The sleeper plate technique is a viable option in younger children with congenital abnormalities, however, continued monitoring of alignment is necessary after screw removal to check for rebound and tethering.


Email: