General Principles

All repairs should be repaired in full extension. Repairs should be immobilised in full extension for 6–12 weeks. Gradual resumption of motion in a hinged brace over an additional 6–8 weeks almost always yields flexion to at least 90 degrees. Marlex mesh has been shown to be an excellent replacement as well as an augment for deficient soft tissue.

Acute tibial tuberosity avulsion

Open repair is best accomplished with a non-absorbable heavy Krackow suture, secured distally around a screw and washer followed by 6 to 8 weeks of immobilization. Augmentation with a semitendinosus graft or Marlex mesh can provide additional support.

Acute Patella Tendon Rupture

End-to-end repair is standard, but re-rupture is not uncommon, so supplemental semitendinosus reconstruction is recommended. The tendon is harvested proximally, left attached distally and passed through a transverse hole in the inferior patella. The gracilis tendon can be harvested and sutured to semitendinosus for additional length, if needed.

Acute Quadriceps Tendon Rupture

These can be repaired end-to-end with a non-absorbable heavy Krackow suture. A superficial quadriceps fascial turndown or mesh may be a useful adjunct.

Patella Fracture

Treatment depends on the status of the patellar component and the loss of active extension. If the component remains well fixed and the patient has less than a 20-degree lag, non-operative treatment in extension. A loose component and/or > 20-degree extensor lag requires ORIF +/− component revision.

Chronic Disruptions

While standard repair techniques are possible, tissue retraction usually prevents a “tension-free” repair. If the patella remains viable and has not retracted proximally an Achilles tendon graft is appropriate. In chronic disruptions with loss of the patella, allograft extensor mechanism reconstruction may be considered. Marlex mesh repair has also been shown to be effective in reconstruction of chronic patellar and quadriceps tendon defects.