Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

79 – LONG-TERM OUTCOME IN MODERN HIP RESURFACING ARTHROPLASTY; A MINIMUM OF 10 YEARS FOLLOW-UP



Abstract

Purpose: The modern generation of hip resurfacing arthroplasties was developed in the early 1990’s with one of the original designs being the McMinn Resurfacing Total Hip System. This was a hybrid metal on metal prosthesis, with a smooth hydroxyapetite coated press fit mono block cobalt chrome shell with a cemented femoral component. Although no longer produced in this form, lessons may be learned from this original series of components. With metal on metal resurfacing arthroplasty now facing criticisms and concerns with regard function, bone preservation capability and soft tissue issues such as ‘pseudotumors’, it is the aim of this long-term study to assess the outcome and survival of an original series of resurfacing arthroplasties.

Method: 27 resurfacing arthroplasties were performed in 25 consecutive patients between June 1994 and November 1996. 16 right hips and 11 left were performed in 14 female patients and 11 male patients. The average age at the time of surgery was 50.5 years (SD 7.9, range 30–63). All surgeries were performed by a single surgeon using a posterior lateral approach. Following the initial early care, each patient received bi-annual follow up along with open access to the clinic with any concerns or complications. A retrospective review of the case notes was conducted and outcome scores retrieved from a prospectively updated database. Radiographs were analyzed and a Kaplan Meier survival chart was constructed for the group.

Results: At latest review 3 patients have died (5yrs, 8yrs and 13.8yrs) and 1 patient has been lost to follow up (5yrs). 7 resurfacings have required revision, all due to acetabular loosening, at a mean follow up of 7 years 11months (SD 2.03years, range 4–10). Metallosis was documented in 4 of the revision cases, however no extensive soft tissue inflammation or ‘pseudotumor’ identified. The mean follow up of the remaining 16 hips is 12years and 10months (SD 12.8months, Range 10.4yrs-14.0 years). The Kaplan Meier survival at a minimum follow up of 10 years is 75.8% (95% CI 0.67–0.95). Mean Oxford hip scores at latest follow up was 20.6 (SD 8.8, range 12–38). There was no significant difference between cup inclination angles for the surviving cohort and those who required a revision procedure with mean cup inclinations of 52.5 (SD 5.5, range 45–60) and 58 degrees respectively (SD 9.1, range 50–70)(p=0.255).

Conclusion: This original series of hip resurfacings, with up to 14 years follow up, shows a survival of 76% at the minimum follow up of 10 years. All failures were due to loosening of the smooth backed acetabulum, which with a modern porous coating, failure may have been avoided or delayed. Despite high inclinations angles no soft tissue reactions were identified within this series. No femoral failures were identified suggesting unlike much literature focus, long-term failure may not be related to the femoral head or neck.

Correspondence should be addressed to: COA, 4150 Ste. Catherine St. West Suite 360, Westmount, QC H3Z 2Y5, Canada. Email: meetings@canorth.org