Abstract
Dislocation following total hip arthroplasty is one of the most common complications, occurring in 1% to 5% of all cases. Several causes for dislocation have been suggested that
-
Mismatching of cup positioning and stem anteversion
-
Impingement between cup and neck of stem prosthesis.
Most often positioning of the stem is anatomically predetermined, while the orientation of the cup is much more flexible. Since July 2005, stem first method has been applied for all cases. During this method, canal preparation and stem trial was done first, and then cup orientation was determined according to the stem direction and impingement. For the bigger cups 34mm or 38mm heads were applied in this series. In the present study dislocation ratio was compared to cup first method.
In the stem fist group (SF), the following procedures were done consequently.
-
Canal was prepared for the stem. Revelation lateral flare high proximal load transfer stem (DJO) was mainly selected. But for the case with high anteversion over 50 degrees, Modulas; conical distal load transfer stem with modular neck (Lima) was selected.
-
According to the stem anteversion and neck length, cup position and orientation were determined. (For the cases with higher anteversion, less cup anteversion was selected, and for some cases higher cup position was selected.
-
According to the cup size 28, 34, or 38 mm diameter neck was selected.
From October 2002 to July 2008, there were 191 THA cases. There were 81 hips in Standard group and 109 hips in SF group. There were 63 females and 18 males in Standard group and 90 females and 19 males in SF group (p=0.41). Average age was 61.0(22–81) in Standard group and 60.2(29–89) in SF group (p=0.53). In Standard group, 64 were replaced for osteoarthritis, 15 for rheumatoid arthritis and two for avascular necrosis. In SF group, 86 were replaced for osteoarthritis, 17 for rheumatoid arthritis and six for avascular necrosis (p=0.53). As for Crowe’s classification, 61 type I, 18 type II and 2 type III were included in Standard group. And 88 type I, 15type II, 4 type III and 2 type IV were included in SF group (p=0.29). Average anteversion of femoral neck were 23.1(−2 to 70) degree in Standard group and 26.2(−4 to 65) degree in SF group measured with CAT scan (p=0.274). MoM bearing surfaces were used with 71 hips (87.7%) in Standard group and 100 hips (91.7%) in SF group (p=0.35). Only in SF group, big metal head were used in 24hips(22%) with 34mm and in 12hips(11%) as 38mm diameter. Average leg length difference between pre and post operation was 11.5mm(0 to 36) in Standard group and 8.0mm(−18 to 30) in SF group (p< 0.05). Average cup inclination was 43.2(25 to 84) degree in Standard group and 40.9 (22 to 66) degree in SF group (p< 0.05). Average cup anteversion was 8.2 degree (0 to 22.8) in Standard group and 7.1 degree (−12 to 30.5) in SF group (p< 0.05). Average operating time was 111.9min (67–150) in Standard group and 97.5min(60–162) in SF group (p< 0.05). Average intra operative hemorrhage was 744ml(10–2757) in Standard group and 487ml(10–1374) in SF group (p< 0.05). The dislocation rate was decreased from 3.7% (3/81 cases) in Standard group to 0.0% (0/109) in SF group.
In conclusion our study suggested that Stem first method and utilization of big metal head would decrease the dislocation rate in primary cases. More bleeding from canal during accetabular reaming was expected. However less bleeding was observed in SF group.
Correspondence should be addressed to Diane Przepiorski at ISTA, PO Box 6564, Auburn, CA 95604, USA. Phone: +1 916-454-9884; Fax: +1 916-454-9882; E-mail: ista@pacbell.net