LONG-TERM RESULTS OF CEMENTLESS FULLY HAC COATED ACETABULAR CUPS IN PRIMARY ARTHROPLASTY OF THE HIP



Abstract

We aim to report the clinical, radiological outcome of consecutive primary hip arthroplasties using the JRI-Furlong Hydroxyapatite ceramic coated acetabular components. We reviewed 412 consecutive primary THA using fully coated acetabular shell in 392 patients, with minimum 12-year follow-up to 18 years, performed at two institutions. Twenty (22 THA) were lost prior to 12-year follow-up, leaving 372 patients (390 THA) available for study.

Fully HAC coated stems were used in all patients. Clinical outcome was measured using Harris, Charnley Oxford, EuroQol EQ-5D scores. Radiographs were systematically analysed for implant position, loosening, migration, osteolysis. Polythene wear was digitally measured.

Mean age was 74.4 yrs. Dislocation occurred in 10 patients (3 recurrent). Revision operations were performed in nine patients (1.9%). Four acetabular revisions were performed for aseptic loosening. Other re-operations were for infection (3), periprosthetic fractures (1), cup malposition (1), revision of worn liner (3). The mean Harris and Oxford scores were 87 (78–97) and 19.1 (12–33) respectively. The Charnley score was 5.6 (5–6) for pain, 5.2 (4–6) for movement and 5.3 (4–6) for mobility. Migration of acetabular component was seen in 4 hips. Acetabular radiolucencies were present in 54 hips (9.7%). The mean linear polythene wear was 0.06mm/year. Mean inclination was 48.4 deg(38–65). Mean EQ-5D description scores and health thermometer scores were 0.81 (0.71–0.89) and 86 (64–95). With an end point of definite or probable loosening, the probability of survival at 12 years was 96.1%. Overall survival at 12 years with removal or repeat revision of either component for any reason as the end point was 94.2%.

The results of this study support the continued use of a fully coated prosthesis and documents the durability of the HAC coated components. In our clinical experience, the Furlong prosthesis revealed encouraging radiographic stability over a long term period