3.P.30 BELOW KNEE AMPUTATION THROUGH A JOINT SPARING PROXIMAL TIBIAL ENDOPROSTHESIS USING A CUSTOM MADE END CAP



Abstract

This case highlights the close association between osteo-fibrous dysplasia (OFD) and adamantinoma, drawing attention to the role for more radical treatment options when treating OFD. We discuss the advancements in joint-sparing endoprostheses using bicortical fixation. Finally we describe a unique biomedical design allowing for manufacture of an end cap to allow amputation through a custom made joint-sparing proximal tibial replacement as opposed to an above knee amputation.

A 37 year old presented 7 years ago having sustained a pathological fracture of her tibia. Subsequent biopsy revealed OFD, curettage with bone graft was performed. She later developed recurrence, two percutaneous biopsies confirmed OFD. 6 years following her initial diagnosis she was referred to RNOH with further recurrence, a biopsy at this stage revealed a de-differentiated adamantinoma. A joint-sparing proximal tibial replacement was performed and adjuvant chemotherapy administered, she remained well for one year. Recurrence was noted at the distal bone-prosthesis interface, histology revealed a high grade dedifferentiated osteosarcoma, limb preservation was not deemed possible and an amputation was performed through the prosthesis. The proximal tibial device was uncoupled leaving a residual 7 cms insitu, a small custom made end cap was attached to the remaining prosthesis and a myocutaneous flap fashioned over it, this ultimately enabled the patient to mobilise well with a below–knee orthotic device.

This case highlights the need for more radical surgery when treating cases of OFD and the relationship between OFD and adamantinoma. It also introduces a joint-sparing proximal tibial device for use in proximal tibial tumours that do not invade the proximal tibial metaphysis. The biomechanical design solution has given us the unique option of preserving the knee joint allowing the patient a below knee amputation whereas previously an above knee amputation would have been performed thereby significantly reducing her functional outcome.

Correspondence should be addressed to Professor Stefan Bielack, Olgahospital, Klinikum Stuttgart, Bismarkstrasse 8, D-70176 Stuttgart, Germany. Email: s.bielack@klinikum_stuttgart.de