Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

THE IPSILATERAL LAMINA AS A GUIDE FOR SCREW TRAJECTORY IN POSTERIOR INSTRUMENTATION OF THE SUB-AXIAL CERVICAL SPINE



Abstract

Aim: In sub-axial cervical vertebrae the lamina appears to project perpendicular to the ipsilateral pedicle axis, and forms a reliable trajectory for avoidance of vertebral artery injury in lateral mass (LM) screw placement: the aim is to confirm these observations.

Material and Methods: 51 digital cervical spine CTs (255 vertebrae; 25 female 26 male; mean age 37.4 range:18–80). Exclusions: Severe degeneration, malformation, tumour, trauma.

Measurement (axial view):

  1. Angle of ipsilateral outer lamina cortex to pedicle axis

  2. Virtual screw trajectory 2 mm from and parallel to the lamina was placed through the LM. Potential violation of the transverse foramen and LM width available for screw purchase was assessed

Results: Average lamina-pedicle angle (standard deviation):

  • Females: Right: C3–84.8°(2.6), C4–85.2°(3.1), C5–86.7°(3.3), C6–89.2°(2.5), C7–92.3°(2.4);

  • Left: C3–84.0°(3.1), C4–84.5°(3.9), C5–86.6°(3.7), C6–89.6°(2.6), C7–92.1°(2.3)

  • No significant difference between males and females (P< 0.05)

  • Violation of transverse foramen C3–C7: 0%

  • LM width (trajectory parallel to LM) in millimetres (standard deviation):

  • Males: Right: C3–5.5(0.7), C4–6.1(0.7), C5–6.8(0.8), C6–7.1(1.1), C7–6.1(1);

  • Left: C3–5.2(0.8), C4–5.9(0.8), C5–7(1.2), C6–7.3(1.1), C7–6.3(1.4)

  • Females: Right: C3–5.3(0.8), C4–5.5(0.9), C5–6.6(1.2), C6–6.3(1.3), C7–5.4(1.4);

  • Left: C3–5.2(1), C4–5.7(1), C5–7.1(1.1), C6–6.5(1.3), C7–5.5(1.6)

Conclusion: The angle formed by the lamina and ipsilateral pedicle ranges from 84° at C3 to 92° at C7. Although the angle is not exactly perpendicular at all levels as hypothesised, the lamina forms a useful reference plane for pedicle screw insertion in the sub-axial cervical spine.

LM screws placed parallel to the lamina find sufficient LM width and are highly unlikely to injure the vertebral artery in bi-cortical placement. This technique appears favourable over conventional 30° LM placement.

Ethics approval: None needed

Interest Statement: None

Correspondence should be addressed to BASS/BCSS c/o BOA, at the Royal College of Surgeons, 35–43 Lincoln’s Inn Fields, London, WC2A 3PE, England.