Abstract
Introduction: Management of bone loss during revision total knee arthroplasty (TKA) can be challenging. The degree and location of bone loss often dictates the type of prosthesis that can be utilized during revision surgery. The aim of this prospective study was to determine if plain radiographs are adequate in assessing the degree of bone loss around TKA and identify the limitations of plain radiographs for this purpose, if any.
Methods: 205 patients undergoing revision TKA at our institution were included. The indication for revision was aseptic failure in 120 patients and septic failure in the remaining patients. The plain radiographs were evaluated by a research fellow and the attending surgeon. The degree and the location of bone loss around the TKA was determined using the UPenn Bone Loss chart. The degree of real bone loss was then determined intraoperatively.
Results: The predicted amount of bone loss for the tibia based on the AP (p=0.136) and lateral (p=0.702) radiographs correlated well with the intraoperative findings. However, plain radio-graphs underestimated the degree of bone loss around femur, particularly the condyles (p=0.005).
Discussion: Reconstructive surgeons performing revision TKA need to be aware of the limitations of routine radiographs in assessing the degree of bone loss around the femoral component. Hence, patients undergoing revision TKA with suspected bone loss may need to be evaluated by additional imaging techniques and/or alternative reconstructive options need to be available to deal with greater than expected degree of bone loss intraoperatively.
Correspondence should be addressed to Ms Larissa Welti, Scientific Secretary, EFORT Central Office, Technoparkstrasse 1, CH-8005 Zürich, Switzerland