IS IMPLANT REMOVAL NECESSARY FOLLOWING SURGICAL STABILISATION OF PATELLA FRACTURE?



Abstract

To assess the outcome and implant removal rate following surgical stabilisation of patella fracture.

Sixty-seven patients who underwent surgical stabilisation of patella fracture between January 1999 and December 2004 were retrospectively reviewed to determine the adequacy of fracture stabilisation, fracture union and implant removal rate.

Forty-three were men and 24 were women with a mean age of 49 years (ranged 14–90 years). Table below demonstrates the injury, fracture patterns and fixation methods. There were 3 open fractures and associated injuries were noted in 22 patients. All fractures united even though the fixation was inadequate in 46 patients. Two superficial infections responded to oral antibiotics. One patient had revision surgery at 6 weeks. Twenty-two patients required implant removal between 2 and 20 months (average 11 months) for implant related symptoms. Of the 22 (32.8%) patients requiring implant removal, 16/40 (40%) were less than 60 years and 6/27 (22.2%) were over 60 years. Mean follow up in asymptomatic patients was 8 months (3 to 18 months) and in patients with implant related problems was 17 months (10 to 36 months). Four patients were lost to follow up.

Surgical stabilisation by current techniques demonstrated satisfactory fracture union. However, one in three required second surgery for implant related symptoms. In the under 60 years group, the implant removal rate increased to 40%. Newer techniques to avoid skin irritation need to be considered.