Abstract
Background: The aim of this prospective multi-center study was to evaluate the clinical and radiological results of a total of 314 uncemented femoral stem revisions using the modular MRP-titanium system.
Methods: 305 patients (111 males, 194 females, mean age 67.7) with 314 MRP-titanium systems were followed-up for a meantime of 3.2 years (1 to 9 years). Pre- and post-operatively all patients were clinically documented using the Harris hip score. Radiologically, the preoperative bony defects were assessed by the Paprosky classification. Post-operatively, periprosthetic bone remodeling was evaluated on the basis of radiographic evidence of bone apposition or resorption.
The modular MRP-titanium system has proven to be valuable in quite problematic cases of hip revision arthroplasty with extensive femoral defects. The system allows intraoperative adaptation of implant length and antetorsion angle to the actual situation, a feature not provided by non-modular femoral revision implants.
Correspondence should be addressed to Richard Komistek, PhD, International Society for Technology in Arthroplasty, PO Box 6564, Auburn, CA 95604, USA. E-mail: ista@pacbell.net