DEEP FLEXION KINEMATICS IN A PCL RETAINING LATERAL PIVOT KNEE ARTHROPLASTY



Abstract

Contemporary knee implants use a variety of methods to control tibiofemoral motions. Posterior stabilized implants have a post and cam to force the femur posterior with flexion. Most posterior cruciate retaining designs rely solely on this ligament and symmetric tibial surfaces to control tibiofemoral translations. However, many studies have demonstrated poor control of tibiofemoral motion in PCL retaining knees. One strategy to augmenting PCL function is to provide a gait-congruent lateral articulation providing definitive stability in extension while allowing lateral condylar translation in deep flexion. It is unknown whether this design strategy, essentially substituting for the ACL, allows the PCL to function more normally.

Fifteen knees in ten patients with a fixed-bearing, PCL retaining, lateral pivot arthroplasty were observed during maximum flexion kneeling and lunging using fluoroscopy. The tibial insert provides a fully conforming lateral articulation from 0°–70° flexion, allowing lateral AP translation at greater flexion. Recruited on the basis of combined KSS scores > 180 points, patients averaged 72 years, 27.5 BMI, and 12 months post-op. Shape matching techniques were used to determine the 3D pose of the implant components.

Skeletal flexion during kneeling averaged 134° (117°–156°) with 11° tibial internal rotation. Medial condylar contact was 3mm posterior, and lateral contact was 11 mm posterior to the tibial AP midpoint. Skeletal flexion during lunging averaged 122° (106°–146°) with 11° tibialinternal rotation. Medial condylar contact was 1mm posterior, and lateral condylar contact was 9mm posterior to the tibial AP midpoint.

Knees with lateral pivot arthroplasty exhibited flexion comparable to the best reported results in North American patients. Tibial rotation was statistically greater than has been reported for symmetric posterior stabilized or PCL retaining implants for the same activities. Posterior translation of the condyles with flexion beyond the range of full articular congruity is consistent with relatively normal PCL function.

Correspondence should be addressed to Richard Komistek, PhD, International Society for Technology in Arthroplasty, PO Box 6564, Auburn, CA 95604, USA. E-mail: ista@pacbell.net