Abstract
The aim of the study was review all the type B and Type C according with A.O. classification tibial plateau fractures from January 1995 to August 2004 with a minimum follow up of six months. It has been selected all the patients treated with closed surgery. In the treatment of type B fractures we used cannulated screws, sometimes with external fixator. In the treatment of type C fractures we used external fixator. As a result of the technical improvements, in the recent years, external fixation has become a surgical technique not only for the treatment of open fractures but also for the management of comminuted fractures with percutaneous synthesis, since there is no need to open the fracture site. In our recently experience we have used a hybrid fixator which is single-use, pre-assembled and radiolucent.
Correspondence should be addressed to Ariella Neustadt at Studio EGA, Professional Congress Organisers, Viale Tiziano, 19 - 00196, Rome - Italy.
The authors will discuss their experience in the treatment of tibial plateau fractures with closed surgery.