TANTALUM ROD FOR THE TREATMENT OF HUMERAL NON-UNION IN THE ELDERLY



Abstract

Introduction: Non union of the humerus in the ostoeportic bone is a great challenge for the orthopedic surgeon. The non weight bearing nature of this bone together with extreme osteoporosis seen in the elderly had rendered a high degree of failure in different modes of internal fixation of established humeral non union. Tantalum is a trabecullar metal with biomechanical properties similar to bone with a high modulus of elasticity and low rigidity. It is proved both in vitro and in vivo to induce excellent bone and vascular in growth and have been used successfully treating other application in orthopedics. We have introduced the tantalum rod for the treatment of humeral non union in the elderly.

Patients and Methods: Six patients with humeral non-union were selected for tantalum rod implantations. All were above 60 years old. All patients had established non and 4 had failures after previous osteosynthesis. The surgical technique was exploration of the fracture site via a posterior or an anterolateral approach, debridement of the fracture site and intramedullary insertion of a 100 mm x 10 mm tantalum rod. No bone grafting was used. Ancillary fixation included a 4.5 broad DCP plate with screws drilled into both bone and rod or screws alone drilled into the bone and tantalum construct. Follow up period was up to one year.

Results: All fractures united clinically and radiographicaly up to 3 months. All patients achieved satisfactory shoulder and elbow range of motion and regained functional activity. No infection or foreign body reaction was noted.

Conclusion: Intramedullary tantalum rodding is a viable treatment option for the cases in both primary and secondary non union of the humeral shaft in osteoporotic bone.