Purpose: The results of surgical treatment of intertrochanteric hip fractures using a sliding hip screw-plate and Norian-SRS, as an adjuvant means of stabilization, are presented.
Material – Methods: 103 patients (27 male, 76 female) with intertrochanteric hip fractures, were treated with a sliding hip screw. Their age ranged from 56 to93 years (av. 68,9y) . In group A (50 patients) we only used a sliding hip screw -plate, while in group B ( 53 patients) we also used Norian-SRS above the upper surface of the sliding hip screw.
Results: Postoperative follow-up ranged from 5 to17 μnνϵς. Mobilization was initiated on the 2nd day with partial weight bearing. A group progressed to full weight bearing in 3 , while B group in 2 months. 8 patients in group A and 2 in group B developed varous deformity. Screw cut out developed in 5 patient of group A and none of group B. Backsliding of the screw ranged from 0 to 16 mm. (av. 4,95 mm.) in group A and from 0 to16mm. (av. 3,25mm.) in group B.
Conclusion: Norian-SRS augmentation of intertrochanteric hip fractures treated with a sliding hip screw-plate, increases the stability of the osteosynthesis, permitting earlier rehabilitation and mobilization of the patient and leading to better functional results.