ON THE INFLUENCE OF JOINT GEOMETRY AND THE USAGE OF DEFECT FILLINGS ON OSTEOCHONDRAL HEALING: A BIOMECHANICAL PERSPECTIVE

7th Congress of the European Federation of National Associations of Orthopaedics and Traumatology, Lisbon - 4-7 June, 2005



Abstract

Although osteochondral defects (OCD) following trauma, sport or degenerative diseases occur frequently, healing remains an unresolved clinical problem. These defects seem to appear more often in convex surfaces than in concave ones.

In vivo studies have demonstrated the influence of mechanical conditions on osteochondral repair[1]. However, the influence of the local joint curvature on the mechanical environment as well as the effect of defect fillings on healing remained unknown. We hypothesize that healing of OCD is strongly affected by the local mechanical environment generated after variations in the joint geometry specifically on concave and convex joint surfaces.

To study spontaneous repair, OCD (mm, 1.5mm depth) in 18 minipigs were created. Based on this knowledge, a predictive biphasic finite element model for tissue differentiation was created to simulate osteochondral healing. The model was validated by comparison of simulated healing with histological and histomorphometrical outcomes. Differentiation was regulated by the combination of a mechanical stimulus with a factor for differentiation defined for each tissue. The mechanical conditions arising from different predesigned defect fillings have been evaluated: Grafts with 100% (P1) and 50% (P2) of the native subchondral bone stiffness were analyzed.

The healing pattern was in general qualitatively comparable to the findings of a gross examination of the histological sections. Generally, the pattern appears to be almost independent of the joint curvature. More hyaline cartilage (HC) was formed in the concave model during simulated healing. The maximum percentage of HC during the simulations was smaller and occurred earlier in the one (27 vs. 40%). In vivo 33% of HC was registered in the 12th week[2]. Defect filling restoring sub-chondral bone quality (P1) allowed a larger amount of hyaline cartilage formation than a less rigid filling (P2).

Until today the more frequent occurrence of OCD at convex joint surfaces reported in the clinical practice has not been related to the local mechanical environment. This study is the first to demonstrate that this may be related to the mechanical stimulus for healing. In fact, during healing simulation HC formation was affected by changes in the joint surface curvature.

A continuity of material properties in the layers under an OCD, which operates as basis for the newly formed cartilage, is important for the development of a tissue with adequate mechanical quality for load transmission. Indeed hyaline cartilage formation occurs earlier when P1 as when P2 was used.

The use of a predictive tissue differentiation model allows a better understanding of the mechanical aspects of healing. Further analysis is however required before such algorithm may be applied in clinical cases. To consider mechanical factors affecting healing, appear to be of importance.

Theses abstracts were prepared by Professor Roger Lemaire. Correspondence should be addressed to EFORT Central Office, Freihofstrasse 22, CH-8700 Küsnacht, Switzerland.

1 Buckwalter et al. 2003. Iowa Orth J23, 66–74 Google Scholar

2 Bail et al. 2003. Bone.32, 457–67 Google Scholar