ACETABULAR IMPACTION GRAFTING IN CEMENTED TOTAL HIP REPLACEMENT: RESULTS WITH METALLIC MESH USED IN UNCONTAINED ACETABULAR DEFECT

7th Congress of the European Federation of National Associations of Orthopaedics and Traumatology, Lisbon - 4-7 June, 2005



Abstract

Aim: Impaction bone grafting is an established technique for the restoration of bone loss at revision hip surgery. Preformed stainless steel meshes have been recently introduced to augment graft containment. We present our results of acetabular impaction grafting at a mean of 4 years, with particular reference to the use of preformed steel meshes.

Methods: 72 consecutive total hip replacements (7 primary and 65 revision) in 69 patients underwent acetabular impaction grafting with morsellised fresh frozen allograft through a posterior approach. In 47 cases there were uncontained defects (46 segmental or combined deficiencies, one pelvic discontinuity) necessitating the use of a preformed steel mesh, secured with multiple small fragment screws to contain the impacted bone graft. All the operations were done by the senior author in a district general hospital.

Results: At mean follow-up of 4 years (range 18 to 92 months), no case has been lost to follow up. The Merle d’Aubigne Postel hip scores averaged 5.3 (pain), 4.2 (walking ability), and 5.3 (range of movement). (Charnley group A -26 patients, group B -19, group C -24). There were no peri-operative deaths or deep infections. There have been no revisions for septic or aseptic loosening. There were 2 cases of early post operative dislocation which stabilised after closed reduction. One case of recurrent disclocation required cup revision. There was one case of radiographic loosening without cup migration. This patient remains pain free and there are no plans for revision. In all other cases, radiographs suggest graft incorporation, with no significant radiolucent lines, acetabular component or mesh migration. There have been no complications relating to the use of the preformed mesh.

Conclusion: The results of this study are encouraging. By using preformed metallic meshes it is possible to manage all cases of acetabular loss, irrespective of severity, encountered during total hip replacement with acetabular impaction grafting.

Theses abstracts were prepared by Professor Roger Lemaire. Correspondence should be addressed to EFORT Central Office, Freihofstrasse 22, CH-8700 Küsnacht, Switzerland.