Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

FAT EMBOLISM AND CARDIOVASCULAR CHANGES FOLLOWING VERTEBROPLASTY IN AN ANIMAL MODEL. IS THE CEMENT TO BLAME?

7th Congress of the European Federation of National Associations of Orthopaedics and Traumatology, Lisbon - 4-7 June, 2005



Abstract

Purpose: To investigate the effect of pressurizing vertebral bodies during vertebroplasty using different materials in the development of fat embolism (FE) and any associated cardiovascular changes.

Polymethylmethacrylate (PMMA) is the material of choice for vertebroplasty (VP). However, PMMA has several disadvantages such as exothermic curing, uncertain long-term biomechanical effects and biocompatibility. As a result alternative materials are being developed to overcome these problems.

In order to determine the role of PMMA in the generation of cardiovascular changes following vertebroplasty we compared injection of cement with wax in an animal model.

Method: In twenty sheep, four vertebral bodies were augmented either with PMMA or bone wax. Heart rate, arterial, central venous and pulmonary artery pressure, cardiac output and blood gas values were recorded. At postmortem the lungs were subjected to histological evaluation.

Results: The consecutive augmentation of four vertebral bodies with PMMA induced cumulative fat embolism causing significant deterioration of baseline mean arterial blood pressure (MABP) and blood gas values. Injection of bone wax resulted in similar cardiovascular changes and amount of intravascular fat in the lungs.

Conclusion: In this animal model cardiovascular complications during multiple VP happen regardless of the augmentation material used. The deteriorating baseline MABP during VP is associated with the pressurization and displacement of bone marrow/fat into the circulation rather than caused by polymethylmethacrylate.

Theses abstracts were prepared by Professor Roger Lemaire. Correspondence should be addressed to EFORT Central Office, Freihofstrasse 22, CH-8700 Küsnacht, Switzerland.