Abstract
Introduction and Aims: There is good preliminary evidence that Bone Morphogenic Protein 7 (BMP-7) plays an integral role in fracture healing and metabolism of bone. It is not known, however, whether the implantation of an OP-1 device will enhance the rate of fracture healing in the presence of osteoporosis. The object of this study was to determine the effects of OP-1 on osteoporotic fracture healing in rats.
Method: An open fracture of the mid-shaft of the femur was created in 60, three months post-surgical ovarectomised female Sprague Dawley rats. Thirty rats had OP-1 device with CMC putty implanted into the fracture site and 30 rats had CMC putty implanted without OP-1. The fracture was stabilised with a 1.4mm K-wire. Muscle and skin closed. Ten rats from each group were sacrificed at three time points – 12, 20 and 31 days post-surgery, and bilateral femurs harvested. The fractured femurs were analysed by DEXA scanning, high-resolution radiography, cross-sectional area, biomechanical assessment and histology.
Results: There was a statistically significant acceleration of fracture healing with the use of OP-1 in DEXA, radiological, cross-sectional area and biomechanical analysis and a qualitative enhancement by histological analysis.
Conclusion: The results show that an OP-1 device can enhance fracture healing in the presence of osteoporosis in a rat.