Full Access

OUTCOME FOLLOWING ACROMIO-CLAVICULAR JOINT RECONSTRUCTION USING THE NOTTINGHAM SURGILIG – PRELIMINARY REPORT



Abstract

Purpose: To analyse preliminary outcomes of a new synthetic ligament used for reconstructing coraco-clavicular ligament in acromio-clavicular joint disruption.

Methods: Patients who underwent acromio-clavicular joint stabilisation using Nottingham Surgilig were followed up at average of 40 months (range 6–80 months) post operation. Apart from clinical and radiological assessment, the Constant-Murley scoring system and the Imatani scores were also used to measure outcome.

Results: Twenty patients underwent this operation and data was available on 19 of them. These patients had their operation after an average of 18 months following injury, during which period they had conservative treatment, except in 2 cases where a Weaver Dunn operation was performed initially.

The mean Constant score was 88 (s.d. 12). The mean Imatani score was 86 (s.d. 16). Most patients were satisfied with the operation (90%). There was one case of rupture through the central portion of the Surgilig, and following extensive laboratory analysis, the ligament has been modified since. One patient had a fracture of his coracoid while lifting heavy weights. In 4 patients there was clinical and radiological evidence of loosening of the screw but only 1 complained of this being a problem.

Conclusion: This is an initial medium term outcome analysis of the Nottingham Surgilig. Our results are promising and justify further use and evaluation of this relatively new technique.

Correspondence should be addressed to BESS c/o BOA, 35-43 Lincoln’s Inn Fields, London WC2A 3PE