Abstract
Purpose of the study Function is strongly infl uenced by proprioceptive ability, this prospective longitudinal study aimed to evaluate the change in proprioceptive performance after knee replacement; comparing total to unicompartment replacement.
Methods and Results Two groups of patients with OA as diagnosed clinically and by X-ray were recruited. Group 1 consisted of 15 patients (mean age 65.8yrs range 57-72yrs, 10 females & 5 males) listed for Total Knee Arthroplasty (TKA) with the AGC (Biomet, UK). Group 2 consisted of 19 patients (mean age 65.5yrs range 52–75yrs; 9 females & 10 males) listed for Oxford Uni-compartmental Knee Arthroplasty (OUKA) for medial compartment OA. The ACL and PCL were present and preserved in all patients in Group 2, while only the PCL was preserved for Group 1 patients.
Joint Position Sense (JPS) & sway were used as measures of proprioception performance. Both groups were assessed pre- and 6 months post-op. JPS was measured using an isokinetic dynamometer (KinCom, Chatanooga Ltd) as the error in actively and passively reproducing fi ve randomly ordered knee fl exion angles (30°, 40°, 50°, 60° and 70°). Sway (area, path and velocity) was measured during single leg stance using a Balance Performance Monitor (SMS Medical) for 30-second interval. Functional outcome was assessed using the Oxford Knee Score (OKS).
Pre-operatively, no differences in JPS or sway were found between limbs in either group. No differences existed between the two groups.
Post-operatively, both groups had signifi cant improvement of JPS in the operated limb only (Mean ± standard deviation for UKA 4.64±1.44° and for TKA 5.18±1.35°). No changes in JPS were seen in the control side. Group 2 patients showed signifi cant improvement in both sway area and path (p< .0001) for both limbs post-operatively. No signifi cant post-operative changes in sway occurred in either limb of Group 1 patients.
The OKS improved post-operatively in both groups, rising from 21.4 to 35.5 for Group 1 patients and from 23.9 to 38 for Group 2 patients.
Conclusion Interestingly, joint position sense improved for both groups but did not seem to show any difference between UKA and TKA. Postural sway was infl uenced by joint replacement type. Ligament retention may contribute to improved global postural control seen after unicompartmental knee arthroplasty and may explain the higher level of function seen in these patients.
Correspondence should be addressed to Roger Smith, Honorary Secretary, BASK c/o Royal College of Surgeons, 35 – 43 Lincoln’s Inn Fields, London WC2A 3PN