Abstract
The aim of the study was to evaluate the results of the LISS system for distal femur fractures.
Eighteen consecutive patients with fractures of the distal femur treated with the LISS system were followed until fracture union. This group included intra-articular, extra-articular and periprosthetic fractures occurring from both high and low energy trauma.
Fractures united in 17 out of 18 cases and only 1 patient required bone grafting. The patient with the fracture that didn’t unite had an early above knee amputation for major pressure areas and peripheral vascular disease. There were no infections but 2 cases of plate failure proximally.
The LISS system is a good treatment option for fractures of the distal femur in both the osteoporotic patient and the patient with high energy trauma.
The abstracts were prepared by Jean-Claude Theis. Correspondence should be addressed to him at Department of Orthopaedic Surgery, Dunedin Hospital, Private Bag 1921, Dunedin, New Zealand.