Full Access

CRUCIATE RETAINING AUGMENTABLE PROSTHESIS IN REVISION TOTAL KNEE ARTHROPLASTY



Abstract

Although bone loss and ligamentous instability are usually indications for the use of constraining prostheses in revision total knee arthroplasty (TKA), several reports have documented a high rate of failure with these prostheses. We therefore tried using the cruciate retaining augmentable type prosthesis (NexGen CRA) if a good intraoperative ligamentous balance could be obtained with revision TKA.

CRA was used on nine knees of seven patients with an average age of 71.7 years. The follow-up lasted for an average of 1.6 years. Clinical evaluation consisted of instability ratings, knee score, range of motion and %MA (mechanical axis) as an index of the alignment. These patients showed improvement varus instability from a mean of 7.0° preoperatively to a mean of 1.5° postoperatively, and in valgus instability from 5.3° to 1.3°.

The knee score was significantly improved from 41 to 81, but the %MA resulted in an unsatisfactory improvement from −8.8% to 34.0%. The femoral anatomical-mechanical angle (FAMA) was measured as a parameter of bowing deformity of the femur, and the knees were divided into two groups, the bowing group consisting of the knees with an FMA of more than 8° (n=6, average 9.0°), the normal group of knees with an FAMA of less than 7° in FAMA (n=3, average 6.7°). The postoperative %MA showed a mean value of 40.9% for the normal group, and 30.6% in the bowing group. These results demonstrated that the discrepancy between FAMA for the bowing group(=9.0°) and the valgus angle of the stem of the femoral component (6.0°) was the cause of the malalignment in the bowing group. These clinical results suggest that the cruciate retaining augmentable type prosthesis can be used successfully for selected revision cases, but that malalignment in knees with bowed femora may remain a problem.

The abstracts were prepared by Nico Verdonschot. Correspondence should be addressed to him at Orthopaedic Research Laboratory, University Medical Centre, PO Box 9101, 6500 HB Nijmegen, The Netherlands.