Abstract
Aim: The purpose of this study was to assess the results with use of an oval cementless acetabular component for revision total hip arthroplasty. Methods: 30 hips had an acetabular revision with an cementless oval acetabular component. No patient was lost to follow-up, but one died during the study period. All defects were classiþed during surgery according the AAOS classiþcation. All patients were evaluated radiographically and clinically and were followed for an average of thirty-six months (range, twenty four to fourty eight months). In 21 of the 30 hips no additional bone grafting was necessary. Results: There were 17 segmental defects (type 1), 12 combined defects (type III) and one case of pelvic discontinuity (type IV). At the time of follow-up, 27 (93.1%) of 29 cups were stable. One of the loosening affected the patient with pelvic discontinuity, the other a patient with a combined segmental defect including the medial wall. The average Harris Hip Score improved from 39 points (range: 15–73 points) preoperatively to 89 points (range 68–96 points) postoperatively. Complications included three dislocations without recurrency. The radiological follow-up examinations revealed good osteointegration of 27 implants. All postoperatively remaining defects were completly þlled in by bone at the follow up. Conclusion: The asymmetrical shape of the BOFOR enhanced the primary stabilty on the lateral columns with three point anchorage. We recommend this device when a patient has an oblong-shaped acetabular defect and the surgeon wants to correct an elevated hip center. However, the medial wall of the acetabulum (Kohlerñs line) should be intact.
Theses abstracts were prepared by Professor Dr. Frantz Langlais. Correspondence should be addressed to him at EFORT Central Office, Freihofstrasse 22, CH-8700 Küsnacht, Switzerland.