Abstract
From 1979 to 2002, 131 total hip replacement were performed consecutively in patients less than 30 years of age (13 to 30,7 mean 24;2) in 75 patients (44 in males and 31 in females. Seventy six in 57 patients could have more than 2 years follow-up and will presented hereby. Regarding the type of prosthesis, 59 stem were cemented and 16 cementless. Five different socket were implanted: 6 screw-in metal back: 8 bulky cemented, 23 bulky cementless, 13 metalback press fit with titanium mesh and 26 HA covered.
Underlying diseases were Avascular necrosis in 46, 8 inflammatory disease, 6 after infected articulation, epiphysiolysis in 4 and acetabular fracture in 3.
48 were done primarily, 28 were a revision procedure and 10 had some past history of infection.
Mean follow up was 7,84 years (range 1,13-22,9). One patient (two hips deceased at 1,1 year. One hips was lost to follow-up. 73 had complete clinical and radiological evaluation.
Nine hips were revised from 2,97-18,64 years after the index procedure (mean 8,53). In 7 only the socket was revised, in two both components. Two of these were infected (secondary infection in one). Of the remaining: 45 had no pain, 18 slight uncommon pain, 10 were classified 5 and 8 had some limp.
Radiological evaluation: 56 had no lucent lines nor subsidence, 4 had some radiolucent line none progressive and 1 had a complete lucent line: and is considered as impending failure. In no case osteosysis was documented.
With the exception of socket loosening due to non optimal design of the initial system (bulky alumina cemented or cementless) the overall results are in favor of theis material in young and active patients.
Theses abstracts were prepared by Professor Dr. Frantz Langlais. Correspondence should be addressed to him at EFORT Central Office, Freihofstrasse 22, CH-8700 Küsnacht, Switzerland.