Abstract
There are numerous papers from specialist arthroplasty centres outlining results of total knee replacement. This review was performed as there is little information on results in general orthopaedic centres. All patients received a Duracon/PCA replacement between 1992 and 1996. Patients were assessed clinically, fluoroscopically and completed SF12, WOMAC and IKSS questionnaires. At a mean of 6.7 (5–9) years follow up 93 (78%) were available for review. The average age was 70 years (52–88) with 58% being male. The primary diagnosis was osteoarthritis in 94.3%, with 41 %, 38% and 21 % being Charnley grades A, B and C respectively.
The average IKS knee score was 71.4 (23–96) and functional score 70 (0–100), with 72.7% experiencing none or only mild pain. The SF12 assessment revealed a mean physical score of 38 (14–63) and mental score of 53 (25–67). There were 88.6% of patients satisfied with their knee and 92% would have the operation again if required. There were no deep infections or PE’s but there were 7 superficial infections and 2 DVT’s. A MUA was required in 8 patients. One patient retains a radiologically loose prosthesis at 8 years but had mild pain with stairs only, a WOMAC functional score of 85 and was happy. There was a best-case survival of 94.4% at 5 years. There were 5 knees revised in 5 patients and no revisions of the deceased patients, all surviving greater than 5 years from surgery. These results suggest that those in general orthopaedic centres are a little less reliable than those in specialist centres. However they are acceptable and patient satisfaction remains high.
Correspondence should be addressed to the editorial secretary: Associate Professor Jean-Claude Theis, Department of Orthopaedic Surgery, Dunedin Hospital, Private Bag 1921, Dunedin, New Zealand.