Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

FUNCTIONAL OUTCOME OF EXTENSILE EXPOSURES USED IN REVISION KNEE ARTHROPLASTY



Abstract

Our aim was to evaluate the functional outcome of extensile revision knee exposure techniques.

166 revision total knee arthroplasties requiring an extensile exposure with 2 year minimum follow-up were prospectively studied {81 rectus snips (RS), 42 tibial tubercle osteotomies (TTO), and 43 quadriceps turn-downs (QT)}. Patients were clinically evaluated for knee society score, range of motion (ROM) and extensor lag comparing pre-op and 24 month follow-up appointment findings. Radiological evidence of avascular necrosis (AVN) pre & post operation was recorded. The TTO group was further examined for proximal migration of the tubercle post op.

Pre-operative knee motion (75° & 71°) and knee scores (74 & 70) were lower in revision total knee arthroplasties requiring QT & TTO than those requiring a RS (91° & 84). Post op flexion and knee scores were greater in the RS group (102° & 131) than in the QT (81° & 114) and TTO (84° & 111) groups in whom there was no significant difference. Avascular necrosis of the patella was most commonly seen following QT. In both QT & TTO groups performing a lateral release was significantly associated with AVN of the patella. Extensor lag (> 10°) was seen only in the QT & TTO groups (11% & 8%) in whom there was no significant difference. Tubercle escape (> 2mm) in the TTO group was significantly greater (54%) in those where circlage wires only had been used than in those where a proximal transfixation wire was used (11%).

In conclusion, both QT & TTO groups had similarly poor knee scores & ROM pre & post operation. AVN of the patella for both groups was similar and significantly associated with performing a lateral release. Finally we would conclude that the use of a through wire significantly reduces tubercle escape in TTO fixation.

The abstracts were prepared by Mr Richard Buxton. Correspondence should be addressed to him at Bankton Cottage, 21 Bankton Park, Kingskettle, Cupar, Fife KY15 7PY, United Kingdom