Abstract
To assess the results of this technique for stabilisation of severe spondylolisthesis, 12 patients with symptomatic severe spondylolisthesis underwent this procedure. The slipped L5 vertebra was stabilized using a hollow medullary screw through the posterior part of the body of S1 into the slipped L5 body, supplemented with pedicle screws into L5 and S1 with posterolateral fusion.
At one year follow-up, all but one patient had improved in leg pain. 2 patients were aware of the prominent pedicle screws. 360° fusion was achieved without any progression of spondylolisthesis. Thus 360° fusion for severe L5-S1 spondylo-listhesis can be achieved effectively using this technique.
The abstracts were prepared by Mr Simon Donell. Correspondence should be addressed to him at the Department of Orthopaedics, Norfolk & Norwich Hospital, Level 4, Centre Block, Colney Lane, Norwich NR4 7UY, United Kingdom