Abstract
We used evoked spinal cord potentials (ESCP) for intraoperative diagnosis in 17 cases of traumatic brachial plexus palsy. Forty spinal nerves were directly stimulated during exploration of the brachial plexus and ESCP recorded from the cervical epidural space were compared with simultaneously observed somatosensory evoked potentials (SEP) and myelographic findings. Both SEP and ESCP could be evoked in 21 spinal nerves but ESCP were always more distinct and five to ten times greater in amplitude than SEP. In four nerves, ESCP but no SEP were produced, suggesting that there was continuity from the nerves to the spinal cord. ESCP were obtained from two spinal nerves which appeared to be abnormal on the myelogram. The results show that intraoperative electrodiagnosis by epidural ESCP recordings can provide useful information on the lesions of traumatic brachial plexus palsy.